MFLRC Academy is live. On-demand regulatory training. Lesson 1 is free. Explore→

MFLRC Academy — on-demand training in Health Canada licensing, GMP and quality systems. Browse courses →

MFLRC - MF License & Regulatory Consultants

November 24, 2026 · Pharmaceuticals

EMA's New Q&As on Comparing Quality Attributes for Therapeutic Equivalence

By Mussarat Fatima

PharmaceuticalsRegulatory AffairsQuality Assurance
EMA's New Q&As on Comparing Quality Attributes for Therapeutic Equivalence

For most generic and hybrid medicines, therapeutic equivalence is shown with a bioequivalence study or a clinical endpoint study. In November 2026, the European Medicines Agency (EMA) published a set of questions and answers that describes a different route for certain products: comparing critical quality attributes in the laboratory to support therapeutic equivalence. For sponsors who make topical, inhaled, or other locally acting chemical products, this is one of the clearest statements yet of what the data package needs to contain.

This article sets out what the new Q&As cover, when a quality-based comparison can support therapeutic equivalence, and the practical steps a chemistry, manufacturing and controls (CMC) team should follow to build a defensible comparison. It is written for regulatory affairs and quality leads at generic, hybrid, and specialty pharmaceutical companies, including Canadian sponsors preparing to enter the European market.

Executive summary

The key points for CMC and regulatory teams:

  • The Q&As apply to chemical products and to in-vitro (laboratory) comparison of finished-product quality attributes. Oral products intended for systemic action are outside the scope.
  • Therapeutic equivalence can sometimes be substantiated by comparing the pharmaceutical form, route of administration, composition and critical quality attributes (CQAs), rather than by a clinical or bioequivalence study.
  • The comparison follows a defined ten-step framework, built on a protocol that is approved internally before testing begins.
  • EMA expects at least three reference batches, and typically six to ten, with pooling of batch data discouraged.
  • Failing to find a difference is not the same as proving similarity, so the statistical method and acceptance criteria must be justified in advance.

What are the new EMA Q&As on quality attribute comparison?

The Q&As are a new section of EMA's Quality of medicines questions and answers (Part 2), titled Comparison of quality attributes to demonstrate therapeutic equivalence. Published in November 2026, the section runs from Q1 to Q13. It builds on an EMA reflection paper (EMA/CHMP/138502/2017, adopted in July 2021) that recognized quality-based comparison in principle but did not explain how to carry it out. The new Q&As fill that gap.

Scope matters here. The Q&As apply to chemical products, to in-vitro comparison only, and to finished-product specifications. Oral products intended for systemic action are excluded, because for those the established bioequivalence pathway continues to apply. Where existing EMA guidance already covers a product type, that guidance takes precedence. In short, this is a tool for specific product categories, not a general replacement for bioequivalence testing.

When can quality data support therapeutic equivalence?

Therapeutic equivalence can be shown by a clinical endpoint study or a bioequivalence study, but EMA states it can sometimes also be adequately substantiated just by comparing the pharmaceutical form, route of administration, composition and critical quality attributes. This matters because for some locally acting or topical products, a sensitive clinical or pharmacokinetic study is difficult to run, and a well-designed quality comparison can be the more reliable evidence.

A quality comparison does not lower the bar, it moves it. The sponsor must show that any clinically relevant difference between the test and reference product can be reliably excluded on the basis of the compared attributes. This is a different mechanism from the United States therapeutic equivalence codes we cover in our guide to FDA's therapeutic equivalence guidance and TE codes, and the two should not be confused.

The ten-step comparison framework

EMA sets out a framework for comparing quality attributes in support of therapeutic equivalence. The steps are sequential, and the protocol must be written and approved before any comparison testing starts. In outline:

  1. Define and justify the critical quality attributes (CQAs) that relate to efficacy and safety.
  2. Justify the attributes you treat as non-critical.
  3. Define a similarity condition for each CQA.
  4. Characterise the reference product across a justified number of batches that represent its variability.
  5. Define the statistical method and the acceptance criteria.
  6. Justify the number of batches used.
  7. Write a Quality Attributes Data Comparison Protocol and approve it internally before use.
  8. Test the products side by side, preferably in one analytical campaign.
  9. Analyse the results against the pre-set criteria.
  10. Write a Comparison Report with a conclusion for each CQA and an overall quality-based equivalence conclusion.

How many batches and samples, and can you pool the data?

The batches you choose decide how convincing the comparison is. EMA expects the reference product to be characterised across enough batches to capture its real variability, and it sets clear expectations on where those batches can come from and how they are handled. This is the part of the exercise sponsors most often underpower.

Test batches should be representative of the intended, validated commercial process, at full scale or at a justified pilot scale. Use of sub-batches is not allowed, and data from non-EU batches should not be used for the exercise. For the number of batches, EMA states at least three but typically six to ten for the reference product, with more where variability is high. Pooling of batch data is discouraged, because between-batch variability is difficult to rule out, especially in small datasets.

QuestionEMA expectation
Reference batchesAt least three, and typically six to ten, chosen to represent the variability of the reference product
Batch scale and originFull scale, or justified pilot scale; no sub-batches; no non-EU batches
Pooling batch dataDiscouraged, because between-batch variability is hard to exclude in small datasets
Each strengthCompare in vitro for each strength; bracketing is possible for more than two strengths if justified, but not across different qualitative compositions

Similarity conditions and statistical methods

A similarity condition is the rule that decides whether a given attribute is close enough. EMA describes two main types, chosen by how the attribute links to efficacy and safety. Picking the right one, and justifying it, is central to a defensible comparison.

The first is a maximum allowed difference, where comparing means is the preferred condition for rate-related and strength-related attributes such as assay, in-vitro release testing and in-vitro permeation testing. The second is an overlap of the test distribution with a reference range, which is more suitable for physico-chemical attributes such as viscosity, density, pH and surface tension. Across both, EMA is explicit that failure to demonstrate a difference should not be interpreted as proof of similarity. The method, its justification, the false positive and false negative risks, and the acceptance criteria must all be stated in the protocol, and the acceptance range may widen with the reference product's own variability, including analytical variability.

Specifications, analytical methods and GMP

The comparison feeds directly into the finished-product specification. EMA expects release and shelf-life specifications to be set from the range of results seen across the reference batches, with obvious outliers disregarded, and the test product's specifications should normally not be outside the ranges observed for the reference product. A wide reference range does not justify a wide test specification: where your process is more capable, tighten the specification to your process capability.

Analytical methods used for release and shelf-life testing can cross-refer to Module 3, while any other methods must be described and suitably validated, with discriminative power shown where relevant. Testing must be done at sites approved for GMP release testing, or by a laboratory declared qualified with an effective quality system in place, and the test batches themselves must be manufactured under GMP. The emphasis on validated methods and complete, reviewable data is the same discipline we describe in our guide to audit trail review and data integrity.

Strengths, non-quantifiable attributes and the dossier

Three practical points close the framework. First, a waiver of in-vitro testing for another strength is not allowed: the comparison should be done for each strength, though bracketing can be used for more than two strengths if justified, and never across different qualitative compositions. Second, a quantitative comparison should be provided for all CQAs; where a quantitative comparison is genuinely not possible, a justified alternative approach is needed, for example photographs of microstructures or morphological forms. Third, the protocol and the comparison report belong in Module 3 (section 3.2.P.2.3), with a summary and conclusion that refers back to Module 3 placed in Module 5.

The Comparison Report itself should carry an introduction and scope, the statistical methodology (including the software version) and acceptance criteria, a data summary with calculations and plots, and a discussion and conclusion for each CQA. Any aberrant result still has to be investigated the same way it would in routine quality control, which is why a sound deviation and out-of-specification procedure underpins the whole exercise.

Quality attribute comparison checklist

Use this checklist to test whether your comparison is ready to stand up to assessment:

  • Your product is in scope: a chemical product, compared in vitro on finished-product attributes, and not an oral product for systemic action.
  • CQAs are defined and justified against efficacy and safety, and non-critical attributes are justified too.
  • A similarity condition is set for each CQA, with the right type for rate-related versus physico-chemical attributes.
  • The reference product is characterised across at least three, and typically six to ten, representative batches, with no sub-batches and no non-EU batches.
  • A Quality Attributes Data Comparison Protocol, with the statistical method and acceptance criteria, is approved internally before testing.
  • Test and reference products are tested side by side, preferably in one analytical campaign.
  • Specifications are set from the reference ranges and tightened to your process capability, not widened to match.
  • Methods are validated, testing is done under GMP, and each strength is compared.
  • The protocol and report sit in Module 3 (3.2.P.2.3), with a summary in Module 5.

Common mistakes

These are the errors most likely to draw a question from an assessor:

  • Setting acceptance criteria after seeing the data instead of in a pre-approved protocol.
  • Using too few reference batches to capture the product's real variability.
  • Treating a failure to find a difference as proof of similarity.
  • Widening the test specification to match a broad reference range rather than tightening to process capability.
  • Pooling batch results without first showing there is no between-batch variability.
  • Applying a quality comparison to an oral systemic product, which is outside the scope of the Q&As.

Frequently asked questions

What does EMA require to show therapeutic equivalence using quality data?

EMA asks for a structured in-vitro comparison of the pharmaceutical form, route of administration, composition and critical quality attributes, carried out under a pre-approved protocol with a defined statistical method and acceptance criteria. The comparison must show that a clinically relevant difference between test and reference product can be reliably excluded.

How many batches of the reference product do I need?

EMA states at least three batches, and typically six to ten for the reference product, with more where variability is high. The number should be justified, and the batches should represent the variability of the reference product. Pooling batch data is discouraged.

Does this replace a bioequivalence study?

Not in general. It is an alternative route for specific chemical products compared in vitro, and oral products for systemic action are excluded. Where existing EMA guidance already sets a pathway for a product type, that guidance takes precedence. For many products, a bioequivalence or clinical endpoint study is still required.

Where in the dossier does the comparison go?

The protocol and the comparison report are placed in Module 3, section 3.2.P.2.3. A summary with the conclusion, referring back to Module 3, is placed in Module 5. Analytical methods used for release and shelf-life testing can cross-refer to Module 3.

Can I use batches made outside the EU, or sub-batches, for the comparison?

No. EMA states that sub-batches are not allowed and that data from non-EU batches should not be used for the exercise. Test batches should be representative of the intended, validated commercial process, at full scale or at a justified pilot scale, and manufactured under GMP.

What statistical approach should I use?

It depends on the attribute. A maximum allowed difference, comparing means, is preferred for rate-related and strength-related attributes such as assay and in-vitro release. An overlap with the reference range suits physico-chemical attributes such as viscosity and pH. Whatever you choose, justify it, state the false positive and false negative risks, and remember that failing to find a difference does not prove similarity.

How MFLRC can help

MFLRC supports pharmaceutical sponsors, including Canadian companies entering the European market, with the CMC and regulatory work this framework demands. We help teams define and justify critical quality attributes, design the comparison protocol and its statistical approach, review the data package for gaps before submission, and position the protocol and report correctly in Modules 3 and 5 through our regulatory affairs and dossier support and quality assurance services.

We also connect the comparison to the systems that support it, from analytical method validation to supplier qualification for your reference product and testing laboratories. If you are planning a quality-based therapeutic equivalence submission, a short scoping session can save months of rework.

Conclusion

EMA's November 2026 Q&As give sponsors something they did not have before: a clear, step-by-step expectation for using quality data to support therapeutic equivalence. The route is narrow, limited to chemical products compared in vitro, but for the right product it can be the strongest evidence available. The sponsors who succeed will be the ones who set the protocol first, choose their batches and statistics carefully, and keep the data integrity and change control behind the comparison just as tight as the comparison itself.

For Canadian sponsors in particular, this is one more reason to build EU-ready CMC discipline early, alongside the inspection and supplier expectations we track in our coverage of EMA's international API inspection programme.

Sources and references

Downloadable Resource

Quality Attribute Comparison Protocol Checklist

A print-ready checklist that walks a CMC team through EMA's ten-step framework for comparing critical quality attributes to support therapeutic equivalence, from defining CQAs to the Module 3 comparison report.

File: MFLRC-Quality-Attribute-Comparison-Checklist.pdf

Share with others

Tags

Therapeutic EquivalenceGeneric DrugsBioequivalencePharmaceuticalsEU Pharmaceutical PackageQuality Management System